Add debug logging and fix minor issues

Add printk debug statements to NTC temperature sensor reading and
IR temperature sensor reading. Change NTC loop to use index-based
iteration. Fix missing newline in boot message. Remove unused
watchdog and commented-out code.
This commit is contained in:
zhangyisong
2026-07-09 12:29:50 +08:00
parent eaa5d0c28b
commit aed11ecee8
3 changed files with 37 additions and 5 deletions
+10 -1
View File
@@ -3,6 +3,7 @@
#include <cmath>
#include <zephyr/device.h>
#include <zephyr/drivers/sensor.h>
#include <zephyr/sys/printk.h>
#include <zpp/result.hpp>
namespace ther {
@@ -15,16 +16,22 @@ public:
bool found = false;
sensor_value max_val{};
for (const auto *dev : s_devices) {
for (size_t i = 0; i < NTC_COUNT; ++i) {
const auto *dev = s_devices[i];
if (0 != sensor_sample_fetch(dev)) {
printk("[ntc] #%zu ERR fetch\n", i + 1);
continue;
}
sensor_value val{};
if (0 != sensor_channel_get(dev, SENSOR_CHAN_AMBIENT_TEMP, &val)) {
printk("[ntc] #%zu ERR channel_get\n", i + 1);
continue;
}
printk("[ntc]#%zu = %d.%d°C\n", i + 1, val.val1, val.val2);
if (!found || val.val1 > max_val.val1 ||
(val.val1 == max_val.val1 && val.val2 > max_val.val2)) {
max_val = val;
@@ -40,6 +47,8 @@ public:
}
private:
static constexpr size_t NTC_COUNT = 8;
inline static const device *s_devices[] = {
DEVICE_DT_GET(DT_NODELABEL(pole_ntc1)),
DEVICE_DT_GET(DT_NODELABEL(pole_ntc2)),